Does An Air Compressor Need A PSSR Examination?
Usually, yes. A compressor that stores or delivers air at more than 0.5 bar above atmospheric pressure is part of a pressure system under the Pressure Systems Safety Regulations 2000 (PSSR). Where any pressure vessel in that system, usually the air receiver, reaches 250 bar litres or more (its pressure in bar multiplied by its internal volume in litres), the system needs a written scheme of examination and periodic examination by a competent person. Below that size the scheme and examination duties fall away, but you still have to set safe operating limits and keep the system properly maintained.
If you need a compressor examined or a written scheme drawn up, send the equipment list and site address to info@gsbinspections.co.uk and we aim to come back with a quote within 48 hours.
When A Compressed Air System Counts As A Pressure System
PSSR applies to a pressure system: one or more rigid pressure vessels with their pipework and protective devices, containing or liable to contain a relevant fluid. Compressed gas, air included, is a relevant fluid once it is above 0.5 bar above atmospheric pressure. The regulations’ own definition of pipework includes compressors, so the compressor, the receiver, the connecting pipework, the safety valve and the gauges are treated as one system.
Schedule 1 to PSSR lists the equipment that is excluded. For compressors it excludes only the water cooling system. The compressor and its receiver stay in.
The 250 Bar Litre Test For Air Receivers
Part II of Schedule 1 switches off regulations 5(4), 8, 9, 10 and 14 for a system that contains a relevant fluid other than steam, where the pressure in bar multiplied by the internal volume in litres is less than 250 for each of its pressure vessels. Those are the duties covering the written scheme, the examination, imminent-danger reports and records.
Two examples show how far apart the answers can be. A 50-litre receiver working at 10 bar comes to 500 bar litres, so the full regime applies. A 20-litre tank at 8 bar comes to 160 bar litres, so it does not. The test is applied vessel by vessel, so one larger receiver brings the whole system back into the scheme and examination duties. Steam is never exempt in this way, whatever the size.
What Still Applies To A Small Compressor Under PSSR
Falling under 250 bar litres does not take a compressor outside PSSR altogether. Regulation 7 still says the system must not be operated until its safe operating limits have been established, and regulation 12 still requires it to be properly maintained in good repair, so as to prevent danger. In practice that means knowing the maximum working pressure, keeping the safety valve and gauge in working order, and draining and servicing the receiver as the manufacturer advises.
Who Is Responsible For The Compressor: User Or Owner
For an installed system, the duties sit with the user, meaning the employer or self-employed person who has control of its operation. For a mobile system, one that can readily be moved between and used in different locations, they sit with the owner. HSE gives an air compressor taken from site to site as its example of a mobile system, so a hired site compressor’s written scheme and examinations are normally the hire company’s responsibility, while a fixed compressor in your workshop is yours.
What A Written Scheme Of Examination Covers For A Compressor
Under regulation 8, a qualifying system must not be operated without a written scheme for periodic examination by a competent person. The scheme has to cover all protective devices, every pressure vessel and pipeline in which a defect may give rise to danger, and those parts of the pipework where a defect may give rise to danger. It must be drawn up or certified by a competent person and reviewed at appropriate intervals.
For a typical compressed air installation that usually means the receiver, its safety valve and any pressure-relieving devices, with the competent person deciding which pipework belongs in it. The PSSR inspections page explains how we draw up schemes as well as examining against them.
How Often A Compressor And Air Receiver Are Examined
PSSR sets no single interval for compressed air. Regulation 9 requires the parts in the scheme to be examined within the intervals the scheme specifies, so the answer for your receiver is written in its scheme and in the next-due date on its last report. Two receivers on the same site can have different intervals if their age, condition or duty differ.
Your PSSR Report And The Date On It
After each examination the competent person must send a written report within 28 days, or sooner if the report sets an earlier date for any work. The system must not be operated after a repair deadline or re-examination date in the report unless the work has been done or the examination carried out. Regulation 14 then requires the user to keep the last report, held where an installed system is installed.
If the examiner finds that the system will give rise to imminent danger unless something is done, regulation 10 requires a written report forthwith, which goes to the enforcing authority within 14 days, and the system must not be operated until the work is done.
Servicing A Compressor Is Not A PSSR Examination
A service keeps the compressor running and helps meet the maintenance duty in regulation 12. It does not replace the examination required by the written scheme, and it does not move the date on the last report. Only an examination by a competent person, against the scheme, does that.
Changing Your PSSR Inspection Company For A Compressor
Many compressed air systems are examined by an insurer’s engineer surveyor, and that arrangement can be changed. Nothing in regulations 8 or 9 requires the competent person examining the system to be the one who drew up or certified its scheme, so the examining body can change while the existing scheme stays in force. Send us the scheme and the last report and we can examine against it, or review it if it no longer fits the plant.
Air Compressor PSSR Questions
Does a small compressor need a PSSR examination?
Not if it holds no steam and every pressure vessel in the system is under 250 bar litres. Regulations 8 to 10 and 14 then do not apply, but the safe operating limits under regulation 7 and the maintenance duty under regulation 12 still do.
We hire a site compressor. Who arranges its examination?
A compressor moved from site to site is a mobile system, so the written scheme and examinations are the owner’s duty, which usually means the hire company. Ask them for the current report before it goes to work.
Is it just the air receiver that gets examined?
No. The scheme covers every protective device, every pressure vessel, and any pipework where a defect could give rise to danger. A competent person decides which parts of your system that takes in.
Can we run the compressor past the date on its report?
No. Regulation 9 says the system must not be operated after that date until the examination has been carried out.
Do PUWER and PSSR both apply to a compressor?
They can. PSSR deals with the dangers of stored pressure; the compressor is also work equipment, so the wider duties of PUWER apply to it as a machine.
Book A PSSR Examination For Your Compressor
We examine compressed air systems against existing written schemes, write schemes for new receivers and for systems that never had one, and review schemes that no longer suit the plant. With five engineers, we take on a single workshop receiver as readily as compressed air across several sites, with renewal dates aligned. We sell inspections only, with no equipment, parts or maintenance contracts.
Email the compressor and receiver details, ideally with the data plate figures for pressure and volume, and the site address to info@gsbinspections.co.uk. If you would rather talk it through, call 01782 855481 to speak to one of the directors, both senior engineers, and then send the details in writing so there is a record from enquiry to report.